Series 2510 Percent Oxygen Transmitters
Series 2510 Percent Oxygen Transmitters
Our ALPHA OMEGA INSTRUMENTS™ Series 2500/2510™ Percent Oxygen Transmitters are blind transmitters designed to provide exceptional performance, accuracy, and stability. Percent oxygen measurement ranges are available from 0-2% to 0-100%. It is designed to provide accurate and dependable percent oxygen measurements in a variety of background gases.
Pricing for US, LATAM, and Canada Only.
Outside of US, LATAM, or Canada, please request a quote. sales.hou@process-insights.com
The Series 2500/2510 Percent Oxygen Transmitters enclosure is made from durable polycarbonate and is rated for NEMA 4 (IP 66) service (may change with the addition of certain optional equipment). A 4-20 mADC output is provided that can be used with a data logger, recorder, PLC, DCS, etc. Options include pressure regulators, flow meters, sample filters.
The Series 2500 is a true loop powered version, and the Series 2510 is the AC powered (115/230 VAC, 50-60 Hz) counterpart and is recommended when AC power is available or preferred. Also, available in optional 24 VDC. In addition to the optional equipment mentioned above, the Series 2510 can be equipped with a sample pump.
FEATURES
- A factory Certificate of Performance Verification and Calibration is included at no additional charge. The product performance is verified in accordance with manufacturing specifications using a National Institute of Standards and Technology (NIST) traceable transfer calibrated standard gas mix.
- Wide Number of Ranges: Measure from <0.1% to 100% Oxygen
- Exceptional Speed of Response: Responds Instantaneously to Changes in Oxygen
- Rugged and Versatile Construction: NEMA 4 Housing Withstands Harsh Environments
- Economically Priced: Save Thousands of Dollars vs Other Methods
- Patented Extended Life Sensor: Eliminates Frequent Sensor Replacement
- Acid Gas Resistant Sensor: Eliminates Sample Conditioning for Many Applications
PERFORMANCE
- Measurement Ranges: in percent 0-2, 0-5, 0-10, 0-25, 0-50, and 0-100
- Accuracy¹: ±1% of full scale (± 5% of full scale on ranges ≤ 0-5%)
- Linearity: + 1% of full scale.
- Response Time: 90% of full scale in less than 20 seconds (typical).
- Sensor Type: Long-life Electrochemical Sensor.
- Temperature Compensation: Standard.
- Operating Temperature Range: 40° to 104°F (5° to 40°C)
- Warranty: Two years for the electronics and one year for the sensor
CONSTRUCTION
- Enclosure: Polycarbonate, rated NEMA 4X (IP66) without optional equipment. NEMA 7 (explosion proof) optional.
- Dimensions: 6.5 in. (165.1 mm) height 7.0 in. (177.8 mm) width 3.9 in.(99.06 mm) depth. Note: All dimensions are without optional equipment
- Gas Connections: Quick connect 1/4” OD for plastic tubing or stainless-steel compression fittings for installations with metal sample lines.
- ELECTRICAL
- Series 2500 Loop Powered Trace Oxygen Transmitter Input power 14-32 VDC
- Series 2510 Trace Oxygen Transmitter: Input power 115/230 VAC, 50-60 Hz, or 24 VDC.
- Loop Resistance: 600 ohms @ 24 VDC (consult factory for other resistance values)
SAMPLE GAS CHARACTERISTICS
- Sample Flow Rate: 1.0 to 2.0 standard cubic feet per hour (SCFH) 0.5 to 1.0 liters/ minute (LPM)
- Sample Gas Pressure Limits: 0.1 to 1.5 psig (0.007 to 0.1 kg/cm2)
2510 with 115VAC 0-10% no options |
Series 2510 Percent Oxygen Transmitter. "C" 0-10/100.0 Percent Switch Selectable Range (Calibrated and shipped on the 0-10 percent range, 4-20mA Output scaled based upon switch selection.) Powered by 115VAC. Features a standard enclosure. Includes standard connectors on the sample outlet. Also includes a 4-20mADC analog output. Warranty: 2-year electronics and 1-year sensor. No options included.
|
2510 with 115VAC 0-25% no options |
Series 2510 Percent Oxygen Transmitter. "D" 0-25/100.0 Percent Switch Selectable Range (Calibrated and shipped on the 0-25 percent range, 4-20mA Output scaled based upon switch selection.) Powered by 115VAC. Features a standard enclosure. Includes standard connectors on the sample outlet. Also includes a 4-20mADC analog output. Warranty: 2-year electronics and 1-year sensor. No options included. No Options Application: |
2510 with 115VAC 0-100% no options |
Series 2510 Percent Oxygen Transmitter. "F" 0-10/100.0 Percent Switch Selectable Range (Calibrated and shipped on the 0-100 percent range, 4-20mA Output scaled based upon switch selection.) Powered by 115VAC. Features a standard enclosure. Includes standard connectors on the sample outlet. Also includes a 4-20mADC analog output. Warranty: 2-year electronics and 1-year sensor. No options Included. No Options Application: |
2510 with 115VAC 0-10% flowmeter pump |
Series 2510 Percent Oxygen Transmitter. "C" 0-10/100.0 Percent Switch Selectable Range (Calibrated and shipped on the 0-10 percent range, 4-20mA Output scaled based upon switch selection.) Powered by 115VAC. Features a standard enclosure. Includes standard connectors on the sample outlet; a flowmeter with a control valve on the sample outlet; 115vac sample pump. Also includes a 4-20mADC analog output. Warranty: 2-year electronics and 1-year sensor. Sample Pump Application: |
2510 with 115VAC 0-25% flowmeter pump |
Series 2510 Percent Oxygen Transmitter. "D" 0-25/100.0 Percent Switch Selectable Range (Calibrated and shipped on the 0-25 percent range, 4-20mA Output scaled based upon switch selection.) Powered by 115VAC. Features a standard enclosure. Includes standard connectors on the sample outlet; a flowmeter with a control valve on the sample outlet; 115vac sample pump. Also includes a 4-20mADC analog output. Warranty: 2-year electronics and 1-year sensor.
|
2510 with 115VAC 0-100% flowmeter pump |
Series 2510 Percent Oxygen Transmitter. "F" 0-10/100.0 Percent Switch Selectable Range (Calibrated and shipped on the 0-100 percent range, 4-20mA Output scaled based upon switch selection.) Powered by 115VAC. Features a standard enclosure. Includes standard connectors on the sample outlet; a flowmeter with a control valve on the sample outlet; 115vac sample pump. Also includes a 4-20mADC analog output. Warranty: 2-year electronics and 1-year sensor. Sample Pump Application: |
2510 with 115VAC 0-10% flowmeter regulator |
Series 2510 Percent Oxygen Transmitter. "D" 0-10/100.0 Percent Switch Selectable Range (Calibrated and shipped on the 0-10 percent range, 4-20mA Output scaled based upon switch selection.) Powered by 115VAC. Features a standard enclosure. Includes standard connectors on the sample outlet; a pressure regulator (max 100 psi) with a stainless steel needle valve with 1/4" compression fitting on the sample inlet; a flowmeter without a control valve on the sample outlet. Also includes a 4-20mADC analog output. Warranty: 2-year electronics and 1-year sensor. Pressure Regulator Application: |
2510 with 115VAC 0-25% flowmeter regulator |
Series 2510 Percent Oxygen Transmitter. "D" 0-25/100.0 Percent Switch Selectable Range (Calibrated and shipped on the 0-25 percent range, 4-20mA Output scaled based upon switch selection.) Powered by 115VAC. Features a standard enclosure. Includes standard connectors on the sample outlet; a pressure regulator (max 100 psi) with a stainless-steel needle valve with 1/4" compression fitting on the sample inlet; a flowmeter without a control valve on the sample outlet. Also includes a 4-20mADC analog output. Warranty: 2-year electronics and 1-year sensor. Pressure Regulator Application: |
2510 with 115VAC 0-100% flowmeter regulator |
Series 2510 Percent Oxygen Transmitter. "D" 0-10/100.0 Percent Switch Selectable Range (Calibrated and shipped on the 0-100 percent range, 4-20mA Output scaled based upon switch selection.) Powered by 115VAC. Features a standard enclosure. Includes standard connectors on the sample outlet; a pressure regulator (max 100 psi) with a stainless steel needle valve with 1/4" compression fitting on the sample inlet; a flowmeter without a control valve on the sample outlet. Also includes a 4-20mADC analog output. Warranty: 2-year electronics and 1-year sensor. Pressure Regulator Application: |